Поделиться:

Liner Material | [Sensor Combination] - AXG: Ceramics, PFA - AXW: PTFE, Polyurethane, Natural Soft Rubber, Natural Hard Rubber | ||||
Communication Protocols | HART 7, BRAIN | HART 7, BRAIN, Modbus FOUNDATION Fieldbus PROFIBUS PA EtherNet / IP | |||
Signal Cable Length | 200 m | 100 m | - | ||
Main Function | - Easy Setup Wizard, Trend Graph Display Function - Data Logging Function (with microSD card) - Parameter Backup / Restore / Duplication Function (with microSD card) - Zero Adjustment - Display Test Function - Input/Output Test Function | ||||
Diagnostic Function | [Application Diagnostics] - Electrode Adhesion Detection - Sensor Empty Check - Wiring Connection Diagnosis - Flow Noise Diagnosis - Low Conductivity Diagnosis - Electrode Insulation Deterioration Diagnosis | ||||
[Verification Function] - Built-in Verification - Standard Verification (with FSA130 ADMAG TI Verification Tool) - Enhanced Verification (with FSA130 ADMAG TI Verification Tool) | |||||
Current Signal | Input: 1 ch (Active) Output: 2 ch (Active) | Input: 1 ch (Active) Output: 2 ch (Active / Passive) | |||
Pulse/Status Signal | Output: 2 ch (Active [With / Without Internal Resister] / Passive) | ||||
Status Signal | Input: 2 ch (Dry Contact) Output: 2 ch (Passive) | Input: 1 ch (Dry Contact) Output: 1 ch (Passive) | |||
Alarm Signal | Output: 1 ch (Passive) | ||||
Multiple Languages | English, French, German, Italian, Spanish, Portuguese, Russian and Japanese. | ||||
Safety Integrity Level | SIL2 | ||||
Others | [AXG1A/AXG4A Transmitter, AXG Integral Type] - LCD with improved environmental resistance - Equipped with temperature input terminal for Density correction and Calolie calculation [AXG Flow sensor、AXG Integral Type] - Expand Lining flare diameter, improve Seal reliability - Compatible with high pressure specifications ASME Class 600 - Selectable built-in grounding electrodes | ||||