Поделиться:
CPU-C Halogen leak detector
Detect ALL halogen refrigerants
Certifyed to DELICACY
Microprocessor control
Halogen Leak Detector CPU-C:
General descriptions:
Microcomputer processor control with advanced digital signal collecting and processing ability
6-level single color alarm
Convenient and practical four-key operation keypad
Advanced functions with fast RESET key, 6-level sensitivity adjustable and battery voltage display
Detects all halogenated gases with: Maximum sensitivity up to 14g/yr
Ultimate sensitivity up to 3g/yr
An economic and practical new detector
Main features:
Microprocessor control, advanced digital signal processing
Single color visual display
Seven levels of sensitivity provide an increase of up to 64x
Tactile keypad
Real time sensitivity adjustment
Battery voltage indication
Certified to DELICACY for detecting R134a, R12, R22, etc.
Detect ALL Halogenated Refrigerants
True mechanical pumping provides positive airflow through sensing tip
Cordless and portable, operate on 2 C- cell batteries
14 (35.5cm) flexible, stainless probe
Warm-up time: 6s
One-year warranty
Parameters:
Power supply: DC3V, Size 2 Alkaline batteries(2)
Maximum sensitivity: R12, R22 and R134a have got approved.14g/y
Limit sensitivity: fitting for halogenating refrigeratingmedium 3g/yr
Sensor life expectancy: About 20 hours
Battery life expectancy: About 30 hours under normal condition
Mode: Continous and no limit
Reaction time: Instantaneous
Warm-up time: 6 seconds
Reset time: 2 seconds
Weight: 560g
Size: 22.9cm×6.5cm×6.5cm
Length of the probe: 35.5cm Gross Weight: 1550G/PC
Packing: 8 PCS/CTN
Measurement of the carton: 57×36×39cm
| SLD-300 HEATED DIODE | 1. Work Environment: Temperature 0°c~50°c; 2. Warm up time: <60s 3. Response time: <2s 4. Power supply: 3.7V Li 2200mAh 5. Standby time: >4h 6. Display method: Red and blue LED indicator lights 7. Sensor failure indication 8. Air pump | Heated diode sensor Sensitivity: 3g (0.1 Oz)/year Internal High efficient air pump Power on self-test function Rechargeable lithium battery | |||||
| HLD-200+ NEGATIVE CORONA | 1. Power supply: 3VDC (2XAA battery) 2. Probe life: about 30h 3. Operating temperature: 0~52 4. Battery life: Approximately 30h under normal condition 5. Work mode: continuous, no limitation 6. Response time: Instant 7. Warm-up time: approximately 6s 8.Resetting time: 2s | Power on self-test function Sensitivity: 3g (0.1 Oz)/year Free spare probe, convenient for maintenance Automatic resetting | |||||
| CPU-1G NEGATIVE CORONA | 1.Power supply: 3VDC (2 2XAA battery) 2.Probe life: about 30hrs 3.Working temperature: 0°C~ 52°C 4.Battery life: 30hrs under normal condition 5.Working model: continuous, no limit 6.Response time: instant 7.Warm-up time: about 6s 8.Resetting time: 2s | Tricolor visual display Seven levels of sensitivity provide an increase of up to 64 Touch keypad controls Real time sensitivity adjustment Internal High efficient air pump Sensitivity: 3g (0.1 Oz)/year | |||||
| CPU-C NEGATIVE CORONA | 1.Power supply: 3VDC (2 2XAA battery) 2.Probe life: about 30hrs 3.Working temperature: 0°C~ 52°C 4.Battery life: 30hrs under normal condition 5.Working model: continuous, no limit 6.Response time: instant 7.Warm-up time: about 6s 8.Resetting time: 2s | 6 Level single color alarm Convenient and pratical four-key opeartion keypad Fast RESET KEY An economic and practical Detector Sensitivity: 3g (0.1 Oz)/year | |||||
| WJL-6000 NEGATIVE CORONA | 1.Operating temperature:0~52 °c(30°F~125°F) 2.Battery life:About 50 hours. 3. Response time:Instantaneous. 4. Work mode:Continuous,no limitation. 5. Fixed probe length:20cm 6. Power supply:6V DC four cell batteries. | Adjusted automatically to the best state of detecting Sensitivity: 6g (0.2 Oz)/year Instant response Low voltage alarm light Portable leak detector | |||||
| LD-100 HEATED DIODE | 1. Work Environment: Temperature 0°c~50°c; 2. Warm up time: <60s 3. Response time: <2s 4. Power supply: AA CELLS 5. Standby time: >4h 6. Display method: Red and blue LED indicator lights 7. Sensor failure indication 8. Air pump | Heated diode sensor Internal High efficient air pump Unique Design Status by LED Display 7 grade sensitivity Complies with CE/SAEJ1627 Standards Replaceable Probe Battery Indicator Low Battery Alarm | |||||
| LMC-100 70kg Refrigerant Electronic Scales | 1.Division value: e = 10d; d = 5g; 2.Maximum weighing: 70kg; 3.Linear: ± 3g; 4.Power: 9v; 5.Verification scale: e = 10d; 6.The maximum permissible error: 0≤m≤35, ± 5g (0.01 pound); 7.Pan size: ¢ 23cm * 23cm; 8.Use 9V battery; 9.5 LCD screen LCD display, blue backlight. | Precision Weighing Highlight LCD display, blue backlight, in any environment can read the data. | |||||
| PA-1000-FS3-A-X1 Pressure Transducer | Pressure: -1 to 16 bar Signal: 4 - 20 mA Fitting: Female Protection: IP65 (IP67 with connector) | German Ceramic Chip Excellent Resistance to Corrosion Impact & vibration Resistance, High Precision and High Stability Wide Operating Temperature Range Compact Size The most competitive prices | |||||
| PA-1001-FS3-A-X1 Pressure Transducer | Pressure: -1 to 40 bar Signal: 4 - 20 mA Fitting: Female Protection: IP65 (IP67 with connector) | German Ceramic Chip Excellent Resistance to Corrosion Impact & vibration Resistance, High Precision and High Stability Wide Operating Temperature Range Compact Size The most competitive prices | |||||
Our factory: