Orthopedic durable Surgical Battery Operated Sternum Saw for Thoracic Operation
1.The picture of small animal surgical sternum saw


Aspetic battery transfer ring

charger & battery

2.The description of small animal surgical sternum saw
Techinical data
| Hand Piece | Working Voltage | 14.4V |
| Output Power | ≥20W | |
| Unit rise in temperature | ≤25℃ | |
| Charger | Input Voltage | AC 220V,50Hz |
| Output Power | 14.4V,900mA | |
| Input Power | 30VA | |
| Battery | Voltage | 14.4V |
| Charging time | About 3 hours | |
Oscillations | 0-15000osc /min | |
| Non-load noise | ≤65dB(A) | |
Oscillating amplitude | ≤5°C | |
Standard configuration:
one set drill unit
one charger
one battery
one aspetic battery transfer ring
one drill chuck key
one instruction manual
one Aluminum alloy case
Application:
For application in acetabulum reaming during joint surgery.
With the perfect shape of ergonomic design,whole unit is autoclavable,motor is imported,low noise,
high speed,high proper alignment,long service life. The machine is warranty for 1 year.
Can connect various flexible reamer,reaming changing during the process of surgery is convenient
and quick.
Notes:
1).Sterilize temperature ≤ 135 °C,if the temperature is over 135 °C , the motor will be damaged.
2).Normal bone drill can only hold drill bits less than 6mm,acetabulum reaming drill with big torque,
rpm is around 300,canulate drill is used with nail or K wire ,rpm is around 600.
3).The battery need to be get out of the power tool after surgery.Otherwise the small automatic
discharge of the electric will make the life of the battery short.
4).The battery cannot be sterilized ,it is not autoclavable.
5).The cranial bur must be washed right after the surgery by purger in order to avoid the blood
stick in the bur,then we should make it dry.
6).The battery space in the handpiece of the tool should not have any water,after sterilization.
7).The cranial bur blade is made of medical stainless steel,in order to avoid broken,so it is flexible
and not very hard,it is easy to be attrite,we suggest each blade only use for 1 surgery.
8). The medical electric drill, saw only the equivalent of medical doctors or professional use in
a short time,can not use a long time continuously.
9). Charger power cord should not be traces of oil, solvents and other chemicals, erosion or mechanical
damage, if it is found to be immediately replaced.
10).Users may not disassemble or repair, or responsibility by the user, the Company is not responsible for
repairs. Man-made damage is not covered under warranty, the costs is incurred by the users themselves.
11). The tools need repairing during the warranty period,should be packaged well before transportation.
Advantages:
1).Our whole power tool can be autoclavable.
2).We can autoclavable for 135 degree,with 1.6Mpa,in this way the bacilli and virus which can
not killed by the suffocating will be killed.
3).We use nickel-metal hydride battery is safe in use.
4).The machine has very low noise.
5).Our products has 1 year warranty period.

Shipping:
1)Delivery time: within three days after the receipt of the payment
2)Delivery method: Internal express such as DHL, Fedex, TNT, UPS, goods could also be delivered by air/sea

Warming tips:
Recommandations for Commonly Used Configuration:
Joint Replacement Operation :Oscillating Saw
Acetabulum Reaming DrillTrauma Operation: Canulate Drill,Bone Drill
Torque LimiterCranial Operation : Cranial Drill,Cranial Bur, Bone Drill
Thoracic Operation: Sternum Saw,Oscillating Saw,Bone Drill, Overhual Saw
Warranty & after - sales service:
1.One year for the drill saw, half a year for the battery
2.Goods will be repaired free within guarantee time

orthopedic power drill