Battery | Details | |||||
Normal specification | ||||||
Model | LFP24400H | LFP48200H | ||||
1 | Rated Voltage | 25.6V | 51.2V | |||
2 | Rated Capacity | 400Ah | 200Ah | |||
3 | Rated Energy | 10.24KWH | ||||
4 | Cell Configuration | 8S4P | 16S2P | |||
5 | Battery Cell | 3.2V100AH 32PCS | ||||
Standard Charge | ||||||
1 | Charge operation temperature range | 0~45℃ | 0~45℃ | |||
2 | Rated charge voltage | 27.6±0.2V | 55.2±0.4V | |||
3 | Max charge voltage | 28.4±0.2V | 56.8±0.4V | |||
4 | Overcharge protection | 29.2±0.2V | 58.4±0.4V | |||
5 | Allowed MAX charge current | 220A withstand 30s | 110A withstand 30s | |||
6 | Peak charge current | 240A withstand 5s | 120A withstand 5s | |||
7 | Rated charge current | 200A | 100A | |||
8 | Recommend charge current | <200A | <100A | |||
Standard discharge | ||||||
1 | Discharge operation temperature range | -20~60℃ | -20~60℃ | |||
2 | Output Voltage Range | 20~28Vdc | 40~56Vdc | |||
3 | Recommend Working Range | 23~27Vdc | 46~54Vdc | |||
4 | Discharge Cut-off voltage | 20V | 40V | |||
5 | Allowed MAX discharge current | 440A withstand 30s | 220A withstand 30s | |||
6 | Peak discharge current | 480A withstand 5s | 240A withstand 5s | |||
7 | Rated discharge current | 400A | 200A | |||
8 | Recommend discharge current | <400A | <200A | |||
Communication | ||||||
1 | RS485 | For LCD remote | ||||
2 | CAN | PC control and monitor | ||||