Поделиться:
220V 96VDC rack mount online 3KVA ups with battery pack

Application:
Rack mounted server and other networking equipment
Feature:
Rack convertible
High Frequency and double conversion online technology
Fully digitized microprocessor control
Smart RS232 communication with monitoring software
Optional SNMP card slot
Wide input voltage range
Advanced PFC technology
Self-testing when UPS startup
Advanced battery management
Automatic battery charging in UPS off mode
Lighting and surge protection
Short circuit and overload protection
Network/fax/modem surge protection
Optional extension battery pack
| Model | 1KN/1KS | 2KN/2KS | 3KN/3KS | 6KN/6KS | 10KN/10KS |
| Power Capacity (VA/W) | 1KVA/0.7KW | 2KVA/1.4KW | 3KVA/2.1KW | 6KVA/4.2KW | 10KVA/7KW |
| Input | |||||
| Voltage Range | Load≤60%,55±5V~138±5V; 60%≤Load≤70%,60±5V~138±5V; 70%≤Load≤80%,70±5V~138±5V; Load80%≥80±5V~138±5V. | ||||
| Frequency Range | 46~54Hz(50Hz),or 56~64Hz(60Hz) | ||||
| Phase | Single phase | ||||
| Power Factor | >0.98 | ||||
| Output | |||||
| Voltage Range | 110VAC/115V/220VAC±2% | ||||
| Frequency Range | The same as the utility frequency (Line mode),50Hz±0.2%(Battery mode) | ||||
| Power Factor | 0.7 | ||||
| Waveform | Pure sine wave | ||||
| THD(Full linear load) | <3% | ||||
| THD(Full non-linear load) | ≤8%(Output :110V),≤10%(Output:115/120Vac) | ||||
| Current Crest Ratio | 3:1 Max | ||||
| Overload Capacity | Line mode:108%-150%, for 30s ,then transfer to bypass & alarm; >150%, for more than 200ms , transfer to bypass & alarm. Battery mode:108%-150%, for 30s , then turn off & alarm; >150%, for more than 200ms ,then turn off & alarm. | ||||
| Short-circuit protection | Bypass Mode: the breaker trip off ; AC/Battery mode:Circuit protection,inverter off, fault. | ||||
| Waveform | Pure sine wave | ||||
| Transfer time (AC mode & Battery mode) | 0ms | ||||
| Efficiency | ≥85%(AC mode );≥83%(Battery mode) | ||||
| Battery | |||||
| Type | 12V Sealed Lead-Acid Maintenance free Battery | ||||
| Recharge Time | 8hrs to 90% of capacity after full load discharge | ||||
| LED/LCD Indicators | |||||
| Status | Load Lever/Battery lever,battery,Utility Power,Inverter,Bypass,overload,default. | ||||
| Audible Alarm | |||||
| Condition | Bypass,battery mode,battery low,overload, fault | ||||
| Acoustic Noise | |||||
| At 1 meter distance | <45dBA | <50dBA | |||
| Communications | |||||
| DB-9 Port | RS232 Serial Interface,SNMP(Optional) | ||||
| Operating Temperature | 0~40°C | ||||
| Environmental | |||||
| Storage temperature | 25-55°C | ||||
| Atitude | <1500m | ||||
| Operating Humidity | 0~95% non-condensing | ||||
| Weight | |||||
| Net(kg) | 16.3/9.1 | 33/11.5 | 39/12.3 | 82.5/19.5 | 93.2/21.5 |
| Dimensions | |||||
| W*D*H(mm) | 482.6*450*88(2U) | 482.6*600*130(3U) | 482.6*606*174(4U) | ||
| Battery Pack Size | 482.6*450*88(2U) | 482.6*450*88(2U) | 482.6*600*130 | 482.6*606*174 | |
Product Image:

Produce line


Quality Control Equipment:

Applications:
Computer center,network center,communication system,automation control system or other critical system.

About the company


HKSANTEK'S Quality Policy
Qaulity is a system, quality is a project,it can contains all the activities of the whole factory,HKSANTEK's belief is "behave
ourseleves firstly, then keep the materials &produce in good level, finally assure the products's quality.everyactivity
effect the quality, so every one is the QC staff in factory.
All the running of HKSANTEK Company is compliant with the ISO9001-2008 and ISO 14001-2004